Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Electr Bioimpedance ; 12(1): 34-49, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34966467

RESUMO

We present here the first impedance-based characterization of the differentiation process of two human mesencephalic fetal neural stem lines. The two dopaminergic neural stem cell lines used in this study, Lund human mesencephalic (LUHMES) and human ventral mesencephalic (hVM1 Bcl-XL), have been developed for the study of Parkinsonian pathogenesis and its treatment using cell replacement therapy. We show that if only relying on impedance magnitude analysis, which is by far the most usual approach in, e.g., cytotoxicity evaluation and drug screening applications, one may not be able to distinguish whether the neural stem cells in a population are proliferating or differentiating. However, the presented results highlight that equivalent circuit analysis can provide detailed information on cellular behavior, e.g. simultaneous changes in cell morphology, cell-cell contacts, and cell adhesion during formation of neural projections, which are the fundamental behavioral differences between proliferating and differentiating neural stem cells. Moreover, our work also demonstrates the sensitivity of impedance-based monitoring with capability to provide information on changes in cellular behavior in relation to proliferation and differentiation. For both of the studied cell lines, in already two days (one day after induction of differentiation) equivalent circuit analysis was able to show distinction between proliferation and differentiation conditions, which is significantly earlier than by microscopic imaging. This study demonstrates the potential of impedance-based monitoring as a technique of choice in the study of stem cell behavior, laying the foundation for screening assays to characterize stem cell lines and testing the efficacy epigenetic control.

2.
Analyst ; 140(17): 6079-88, 2015 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-26198701

RESUMO

We present the characterisation and validation of multiplexed 4-terminal (4T) impedance measurements as a method for sensing the spatial location of cell aggregates within large three-dimensional (3D) gelatin scaffolds. The measurements were performed using an array of four rectangular chambers, each having eight platinum needle electrodes for parallel analysis. The electrode positions for current injection and voltage measurements were optimised by means of finite element simulations to maximise the sensitivity field distribution and spatial resolution. Eight different 4T combinations were experimentally tested in terms of the spatial sensitivity. The simulated sensitivity fields were validated using objects (phantoms) with different conductivity and size placed in different positions inside the chamber. This provided the detection limit (volume sensitivity) of 16.5%, i.e. the smallest detectable volume with respect to the size of the measurement chamber. Furthermore, the possibility for quick single frequency analysis was demonstrated by finding a common frequency of 250 kHz for all the presented electrode combinations. As final proof of concept, a high density of human hepatoblastoma (HepG2) cells were encapsulated in gelatin to form artificial 3D cell constructs and detected when placed in different positions inside large gelatin scaffolds. Taken together, these results open new perspectives for impedance-based sensing technologies for non-invasive monitoring in tissue engineering applications providing spatial information of constructs within biologically relevant 3D environments.


Assuntos
Impedância Elétrica , Engenharia Tecidual , Tomografia/métodos , Técnicas de Cultura de Células , Eletrodos , Gelatina/química , Células Hep G2 , Humanos , Tomografia/instrumentação
3.
Analyst ; 140(10): 3623-9, 2015 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-25868456

RESUMO

We investigated the combined effect of the initial cell density (12,500, 35,000, 75,000, and 100,000 cells cm(-2)) and concentration of the anti-cancer drug doxorubicin on HeLa cells by performing time-dependent cytotoxicity assays using real-time electrochemical impedance spectroscopy. A correlation between the rate of cell death and the initial cell seeding density was found at 2.5 µM doxorubicin concentration, whereas this was not observed at 5 or 100 µM. By sensing the changes in the cell-substrate interaction using impedance spectroscopy under static conditions, the onset of cytotoxicity was observed 5 h earlier than when using a standard colorimetric end-point assay (MTS) which measures changes in the mitochondrial metabolism. Furthermore, with the MTS assay no cytotoxicity was observed after 15 h of incubation with 2.5 µM doxorubicin, whereas the impedance showed at this time point cell viability that was below 25%. These results indicate that impedance detection reveals cytotoxic events undetectable when using the MTS assay, highlighting the importance of combining impedance detection with traditional drug toxicity assays towards a more in depth understanding of the effect of anti-cancer drugs on in vitro assays. Moreover, the detection of doxorubicin induced toxicity determined with impedance under static conditions proved to be 6 times faster than in perfusion culture.


Assuntos
Antineoplásicos/farmacologia , Espectroscopia Dielétrica/métodos , Doxorrubicina/farmacologia , Ensaios de Seleção de Medicamentos Antitumorais/métodos , Contagem de Células , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Células HeLa , Humanos , Fatores de Tempo
4.
Biomicrofluidics ; 6(3): 34109, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23908680

RESUMO

A modular microfluidic airways model system that can simulate the changes in oxygen tension in different compartments of the cystic fibrosis (CF) airways was designed, developed, and tested. The fully reconfigurable system composed of modules with different functionalities: multichannel peristaltic pumps, bubble traps, gas exchange chip, and cell culture chambers. We have successfully applied this system for studying the antibiotic therapy of Pseudomonas aeruginosa, the bacteria mainly responsible for morbidity and mortality in cystic fibrosis, in different oxygen environments. Furthermore, we have mimicked the bacterial reinoculation of the aerobic compartments (lower respiratory tract) from the anaerobic compartments (cystic fibrosis sinuses) following an antibiotic treatment. This effect is hypothesised as the one on the main reasons for recurrent lung infections in cystic fibrosis patients.

5.
Bioinspir Biomim ; 4(4): 044001, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19901449

RESUMO

Recent advances in biomimetic membrane systems have resulted in an increase in membrane lifetimes from hours to days and months. Long-lived membrane systems demand the development of both new automated monitoring equipment capable of measuring electrophysiological membrane characteristics and new data processing software to analyze and organize the large amounts of data generated. In this work, we developed an automated instrumental voltage clamp solution based on a custom-designed software controller application (the WaveManager), which enables automated on-line voltage clamp data acquisition applicable to long-time series experiments. We designed another software program for off-line data processing. The automation of the on-line voltage clamp data acquisition and off-line processing was furthermore integrated with a searchable database (DiscoverySheet) for efficient data management. The combined solution provides a cost efficient and fast way to acquire, process and administrate large amounts of voltage clamp data that may be too laborious and time consuming to handle manually.


Assuntos
Materiais Biomiméticos/química , Membrana Celular , Bicamadas Lipídicas/química , Potenciais da Membrana , Membranas Artificiais , Técnicas de Patch-Clamp/instrumentação , Técnicas de Patch-Clamp/métodos , Desenho de Equipamento , Análise de Falha de Equipamento
6.
Biomicrofluidics ; 3(1): 14104, 2009 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-19693397

RESUMO

Two microfluidic systems have been developed for specific analysis of L-glutamate in food based on substrate recycling fluorescence detection. L-glutamate dehydrogenase and a novel enzyme, D-phenylglycine aminotransferase, were covalently immobilized on (i) the surface of silicon microchips containing 32 porous flow channels of 235 mum depth and 25 mum width and (ii) polystyrene Poros beads with a particle size of 20 mum. The immobilized enzymes recycle L-glutamate by oxidation to 2-oxoglutarate followed by the transfer of an amino group from D-4-hydroxyphenylglycine to 2-oxoglutarate. The reaction was accompanied by reduction of nicotinamide adenine dinucleotide (NAD(+)) to NADH, which was monitored by fluorescence detection (epsilon(ex)=340 nm, epsilon(em)=460 nm). First, the microchip-based system, L-glutamate was detected within a range of 3.1-50.0 mM. Second, to be automatically determined, sequential injection analysis (SIA) with the bead-based system was investigated. The bead-based system was evaluated by both flow injection analysis and SIA modes, where good reproducibility for L-glutamate calibrations was obtained (relative standard deviation of 3.3% and 6.6%, respectively). In the case of SIA, the beads were introduced and removed from the microchip automatically. The immobilized beads could be stored in a 20% glycerol and 0.5 mM ethylenediaminetetraacetic acid solution maintained at a pH of 7.0 using a phosphate buffer for at least 15 days with 72% of the activity remaining. The bead-based system demonstrated high selectivity, where L-glutamate recoveries were between 91% and 108% in the presence of six other L-amino acids tested.

7.
Bioelectrochemistry ; 70(2): 199-204, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-16920407

RESUMO

The electroenzymatic reactions of Trametes hirsuta laccase in the pure organic solvent dimethyl sulfoxide (DMSO) have been investigated within the framework for potential use as a catalytic reaction scheme for oxygen reduction. The bioelectrochemical characteristics of laccase were investigated in two different ways: (i) by studying the electroreduction of oxygen in anhydrous DMSO via a direct electron transfer mechanism without proton donors and (ii) by doing the same experiments in the presence of laccase substrates, which display in pure organic solvents both the properties of electron donors as well as the properties of weak acids. The results obtained with laccase in anhydrous DMSO were compared with those obtained previously in aqueous buffer. It was shown that in the absence of proton donors under oxygenated conditions, formation of superoxide anion radicals is prevented at bare glassy carbon and graphite electrodes with adsorbed laccase. The influence of the time for drying the laccase solution at the electrode surface on the electroreduction of oxygen was studied. Investigating the electroenzymatic oxidation reaction of catechol and hydroquinone in DMSO reveals the formation of various intermediates of the substrates with different electrochemical activity under oxygenated conditions. The influence of the content of aqueous buffer in the organic solvent on the electrochemical behaviour of hydroquinone/1,4-benzoquinone couple was also studied.


Assuntos
Técnicas Biossensoriais/métodos , Dimetil Sulfóxido/química , Eletroquímica/métodos , Eletrodos , Lacase/química , Oxigênio/química , Técnicas Biossensoriais/instrumentação , Materiais Revestidos Biocompatíveis/química , Eletroquímica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Compostos Orgânicos/química , Oxirredução , Soluções , Solventes/química , Água/química
8.
Prikl Biokhim Mikrobiol ; 41(1): 64-71, 2005.
Artigo em Russo | MEDLINE | ID: mdl-15810735

RESUMO

Models of microbial biosensors based on 11 strains of degrading surface-active substances (SASs) and polycyclic aromatic hydrocarbons (PAHs) were studied. Substrate specificity, sensitivity, and stability of biosensor models were comparatively evaluated.


Assuntos
Bactérias/metabolismo , Técnicas Biossensoriais , Compostos Policíclicos/metabolismo , Biodegradação Ambiental , Especificidade por Substrato
9.
Talanta ; 65(2): 349-57, 2005 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-18969806

RESUMO

The screen-printed four-electrode system was used as the amperometric transducer for determination of phenols and pesticides using immobilised tyrosinase, peroxidase, acetylcholinesterase and butyrylcholinesterase. Acetylthiocholine chloride was chosen as substrate for cholinesterases to measure inhibition by pesticides, hydrogen peroxide served as co-substrate for peroxidase to measure phenols. The compatibility of hydrolases and oxidoreductases working in the same array was studied. The detection of p-cresol, catechol and phenol as well as of pesticides including carbaryl, heptenophos and fenitrothion was carried out in flow-through and steady state arrangements. In addition, the effects of heavy metals (Cu(2+), Cd(2+), Fe(3+)), fluoride (NaF), benzene and dimethylsulphoxide on cholinesterase activities were evaluated. It was demonstrated that electrodes modified with hydrolases and oxidoreductases can function in the same array. The achieved R.S.D. values obtained for the flow system were below 4% for the same sensor and less than 10% within a group of five sensors. For the steady state system, R.S.D.s were approximately twice higher. One assay was completed in less than 6min. The limit of detection for catechol using tyrosinase was equal to 0.35 and 1.7muM in the flow and steady state systems, respectively. On the contrary, lower limits of detection for pesticides were achieved in the steady state system-carbaryl 26nM, heptenophos 14nM and fenitrothion 0.58muM.

10.
Prikl Biokhim Mikrobiol ; 40(4): 472-7, 2004.
Artigo em Russo | MEDLINE | ID: mdl-15455722

RESUMO

Strain Comamonas testosteroni TI, capable of degrading the nonionic surfactant (NIS) nonylphenolethoxylate (OP-10), was used for constructing a pilot cellular biosensor. The lower NIS detection limit for the biosensor was 0.25 mg/l. We studied the substrate specificity of the biosensor with respect to a wide range of organic compounds: surfactants, polyaromatic compounds (PAC), carbohydrates, alcohols, etc. It was shown that the biosensor based on Comamonas testosteroni TI did not respond to glucose, which was an advantage over the formerly described biosensor based on Pseudomonas rathonis T. The amplitude of the sensor response remained stable for 10 days.


Assuntos
Técnicas Biossensoriais , Comamonas testosteroni , Tensoativos/análise , Técnicas Biossensoriais/métodos , Comamonas testosteroni/metabolismo , Etilenoglicóis/análise , Especificidade por Substrato
11.
Anal Bioanal Chem ; 376(7): 1098-103, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12856095

RESUMO

Screen-printing technology for electrode fabrication enables construction of amperometric devices suitable for combination of several enzyme electrodes. To develop a biosensor array for characterisation of wastewaters, tyrosinase and horseradish peroxidase (HRP) or cholinesterase-modified electrodes were combined on the same array. The behaviour of the tyrosinase-modified electrode in the presence of hydrogen peroxide (required co-substrate for the HRP-modified electrode) and acetylthiocholine chloride (required co-substrate for cholinesterase) was studied. Performance of bi-enzyme biosensor arrays in the batch mode and in the flow-injection system are discussed.


Assuntos
Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Complexos Multienzimáticos/química , Acetilcolinesterase , Técnicas Biossensoriais/instrumentação , Catecóis/análise , Colinesterases , Eletroquímica/instrumentação , Eletrodos , Enzimas Imobilizadas , Análise de Injeção de Fluxo , Peroxidase do Rábano Silvestre , Peróxido de Hidrogênio , Monofenol Mono-Oxigenase , Fenóis/análise , Reprodutibilidade dos Testes , Poluentes Químicos da Água/análise
12.
Talanta ; 61(4): 473-83, 2003 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-18969209

RESUMO

This paper describes the design, development and characteristics of a tyrosinase (polyphenol oxidase) modified amperometric screen-printed biosensor array, with the enzyme cross-linked in a redox-hydrogel namely the PVI(13)-dmeOs polymer. Two types of Au-screen-printed four-channel electrode arrays, differing in design and insulating layer, were compared and investigated. Au-, graphite-coated-Au- and Carbopack C-coated-Au-surfaces, serving as the basis for tyrosinase immobilisation, were investigated and the performances of the different arrays were evaluated and compared in terms of their electrocatalytic characteristics, as well as operational- and storage stability using catechol as model substrate. It was found that the Carbopack C-coated array was the best choice for tyrosinase immobilisation procedure mainly due to a higher mechanical stability of the deposited enzyme layer, combined with good sensitivity and stability for up to 6 months of use. In the batch mode the biosensors responded linearly to catechol up to 30 muM with limits of detection from 0.14 muM. Parameters from cyclic voltammograms indicated that the reversibility of the direct electrochemical reaction for catechol on the three types of electrode surfaces (no tyrosinase modification) was not the limiting factor for the construction and performance of tyrosinase biosensors.

13.
Biosens Bioelectron ; 17(11-12): 1033-43, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12392953

RESUMO

The application of a quinoprotein glucose dehydrogenase modified thick-film sensor as label detector in a capillary immunoassay (CIA) for xenoestrogens is presented. The detection of the alkylphenols and their ethoxylates is based on the competition between the analyte and tracer molecules for the binding sites of anti-alkylphenol ethoxylate antibodies. This assay is performed off-line in small disposable PVC capillaries coated with immobilized antibodies. This format allows the combination of the assay with a small portable device potentially useful for on-site environmental monitoring. Beside high amplification the utilization of beta-galactosidase as enzyme label allows the direct combination with a GDH biosensor at optimal pH conditions. The bioelectrocatalytic properties of this biosensor offer an additional amplification and thus allow a very sensitive quantification of 4-aminophenol, generated by the beta-galactosidase. Detection limits of the analytes in the microg/l range were obtained, while other phenolics and surfactants showed no or very little cross reactivity.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroforese Capilar/instrumentação , Glucose Desidrogenase , Técnicas Imunoenzimáticas/instrumentação , Fenóis/análise , Técnicas Biossensoriais/métodos , Eletroforese Capilar/métodos , Enzimas Imobilizadas , Desenho de Equipamento , Técnicas Imunoenzimáticas/métodos , Miniaturização , Sensibilidade e Especificidade
14.
Water Sci Technol ; 45(4-5): 191-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11936634

RESUMO

The application of amperometric biosensor- and chemiluminiscence based methods for rapid detection of viable E. coli in water has been investigated. An amplification of the amperometric signal by a factor of 4 was obtained when the cellobiose dehydrogenase (CDH) biosensor was used instead of a plain graphite electrode for detection of b-galactosidase (b-GAL) activity at 22.5 degrees C. A linear correlation was demonstrated for detection time (DT) vs. initial concentrations (logarithmic units) of E. coli IT1 and E. coli in environmental samples, respectively, by use of the CDH biosensor or a chemiluminometric technique. The study has shown that an E. coli concentration > or = 10(4) cfu/100 mL in environmental samples was determined by the CDH biosensor within one working day. However, further reduction of the DT can be obtained, e.g. by increasing the signal amplification factor using other biosensors.


Assuntos
Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Escherichia coli/isolamento & purificação , Esgotos/microbiologia , Microbiologia da Água , Poluição da Água/análise , Desidrogenases de Carboidrato/metabolismo , Eletrodos , Escherichia coli/enzimologia , Glucose 1-Desidrogenase , Glucose Desidrogenase/metabolismo , Medições Luminescentes , Fatores de Tempo , beta-Galactosidase/metabolismo
15.
Fresenius J Anal Chem ; 371(4): 456-66, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11760053

RESUMO

This brief overview summarises the immunoassay-based results obtained in the course of two years of the European INCO-Copernicus project BIOTOOLS. The project is aimed at simplifying the procedures for detection of surface active compounds (SAC) using, among others, antibody-based methods, i.e., microtiter plate-based enzyme-linked immunosorbent assays (ELISA), polarisation fluoro immunoassays (PFIA), and enzyme flow injection immunoassays (FIIA). Thirty-three rabbits were immunised with five different sulphophenyl moieties and three p-hydroxyphenyl moieties conjugated to protein immunogens to produce analytical antibodies against linear alkylbenzene sulphonates (LAS) and nonylphenol (NP). Although most of the antibodies exhibited binding reaction in indirect ELISA, only a few showed the required assay sensitivity. The best antibodies for LAS exhibited a 50% binding inhibition at IC50 19.8 microg L(-1) in indirect ELISA. Similar inhibition was observed for direct ELISA using peroxidase tracers. Antibodies against NP allowed the establishment of an indirect assay operating in the mg L(-1) range. A rapid and simple protocol for the screening of NP and LAS using homogeneous PFIA is described. The assay time for 10 samples was 7 minutes, thus allowing fast detection of the selected SAC at the mg L(-1) level. A generic competitive FIIA system, using a protein G column for separation of free and antibody-bound beta-galactosidase (beta-Gal) tracer, was developed for the screening of LAS, NP, and nonylphenol decaethoxylate (NPEO10). The FIIA had a sample throughput (STP) of 5-10 samples per hour, with limits of detection (LOD) for LAS, NP, and NPEO10 of 19.5, 52, and 2.4 microg L(-1), respectively. The developed FIIAs were applied to spiked rain and surface water.


Assuntos
Imunoensaio/métodos , Tensoativos/análise , Animais , Humanos , Coelhos
16.
J Immunol Methods ; 246(1-2): 119-30, 2000 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-11121553

RESUMO

On- and off-line heterogeneous non-competitive flow immunoassays for the determination of Interleukin-10 are described. The sample containing IL-10 is mixed, either on-line in a reaction coil or off-line in a test tube, with fluorescent labelled anti-IL-10 antibodies to form an antibody-antigen complex. The labelled unbound antibodies are trapped on an immobilized IL-10 column whereas the IL-10-antibody complexes are eluted and detected downstream by a fluorescence detector. The optimization of the systems was performed with respect to choice of affinity support, flow rate, carrier buffer additives, pH and antibody-antigen association. Both bio recognition assays were tested with a spiked cell medium and the IL-10 detection limits in this matrix was found to be 8 fmol using the off-line incubation mode and 40 fmol using the on-line incubation mode. The sample through-put was 26 and 40 samples per hour in the on-line and off-line incubation modes, respectively. IL-10 identification in the sample fractions was achieved using MALDI-TOF MS.


Assuntos
Fluorimunoensaio/métodos , Interleucina-10/análise , Reações Antígeno-Anticorpo , Cromatografia de Afinidade , Reações Cruzadas , Humanos , Cinética , Proteínas Recombinantes/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Especificidade por Substrato
17.
Anal Chem ; 72(21): 5280-4, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11080876

RESUMO

To obtain a high degree of selectivity in sample preparation, supported liquid membrane (SLM) extraction was combined with immunologic recognition. The SLM employs a hydrophobic polymer for supporting the immobilization of an organic solvent, thus forming a nonporous membrane. Said membrane separates the aqueous sample on one side (donor) from a receiving aqueous phase on the other (acceptor). The extraction involves the partitioning of neutral compounds between the sample solution, continuously pumped alongside the membrane, and the membrane. From the membrane, reextraction takes place into a second aqueous phase containing antibodies specific for the target compound(s). Hence, there is a formation of an antibody-antigen complex at the heart of the sample preparation (ImmunoSLM). When the immunocomplex forms, the antigen can no longer redissolve in the organic membrane, thus being trapped in the acceptor. Consequently, the concentration gradient of free antigen over the membrane is ideally unaffected, this being the driving force for the process. With a surplus of antibody, the concentration of analyte in the receiving phase will easily exceed the initial sample concentration. In this work, the so formed immunocomplex was quantified on-line, using a fluorescein flow immunoassay in a sequential injection analysis (SIA) setup. The outlined ImmunoSLM-SIA scheme was successfully applied for the extraction of 4-nitrophenol from spiked water solutions as well as from a spiked wastewater sample, indicating that the immunoextraction can be suitable when dealing with difficult matrixes.

18.
Anal Chem ; 72(17): 4171-7, 2000 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-10994980

RESUMO

The aim was to develop a fast generic enzyme flow immunoassay (EFIA) using a beta-galactosidase (beta-GAL) label in combination with colorimetric detection as well as with a new amperometric biosensor as the label detector. The amperometric biosensor was previously developed within the group for the determination of diphenols in surface water samples. Antigen (Ag, analyte), tracer (Ag*, antigen labeled with beta-GAL), and antibody (Ab) were incubated off-line. After the equilibrium was reached, the sample was introduced into the flow system. The antibody complexes, AgAb and Ag*Ab, were trapped in a protein G column while the free unbound tracer was eluted and detected by an amperometric biosensor downstream after substrate reaction. The enzyme label beta-GAL converted the substrate 4-aminophenyl-beta-D-galactopyranoside (4-APG) into 4-aminophenol (4-AP), which subsequently was detected by a cellobiose dehydrogenase (CDH) modified solid graphite electrode. 4-AP was first oxidized at the electrode surface at +300 mV vs Ag/AgCl, and the formed 4-imino quinone (4-IQ) was reduced back to 4-AP by the CDH in the presence of cellobiose. By combining the EFIA with the CDH biosensor, the overall signal of one tracer molecule is amplified at two occasions, i.e., one enzyme label converts the substrate into many 4-AP molecules, and second these are further amplified by the CDH biosensor. The optimum conditions for the EFIA in terms of the molar ratio between tracer and beta-GAL, temperature, flow rate, etc., was investigated with colorimetric detection, using 2-nitrophenyl-beta-D-galactopyranoside (2-NPG) as the beta-GAL substrate. The performance of both the colorimetric and CDH biosensor detection was investigated and both methods were applied for determination of the model compound atrazine in spiked surface water samples. Detection limits of 0.056 +/- 0.008 and 0.038 +/- 0.007 microg L(-1) and IC50 values of 2.04 +/- 0.294 and 0.42 +/- 0.08 microg L(-1) were obtained for colorimetric and CDH detection, respectively. Matrix effects were less pronounced with the CDH biosensor than with colorimetric detection.


Assuntos
Técnicas Biossensoriais , Desidrogenases de Carboidrato/química , Fenóis/análise , Água/análise , beta-Galactosidase/química , Desidrogenases de Carboidrato/metabolismo , Colorimetria , Imunoensaio , Sensibilidade e Especificidade , beta-Galactosidase/metabolismo
19.
J Chromatogr A ; 889(1-2): 195-209, 2000 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-10985551

RESUMO

Seven laboratories participated in an inter-laboratory comparison exercise within the framework of the PRISTINE, SANDRINE and INEXsPORT European Union Projects. Solid-phase extraction (SPE) methodologies were used for the extraction of target analytes from wastewaters. The analytical strategies were based on liquid chromatography (LC) coupled to mass spectrometric (MS) or to fluorescent (FL) detection in all cases with the exception of one laboratory using a test-tube enzyme-linked immunosorbent assay kit. Samples were spiked with the surfactants nonylphenolpolyglycol ether, coconut diethanolamide, linear alkylbenzene sulfonate, nonylphenolpolyglycol ether sulfate, alkylpolyglycol ether and secondary alkane sulfonate. After enrichment on previously conditioned SPE cartridges, the SPE cartridges were distributed among the participating laboratories without the information about the amount of spiked surfactants. In addition, SPE cartridges loaded with a real-world environmental sample containing a tannery wastewater were also analyzed. The results of the programme showed that SPE followed by LC-MS techniques are reliable for the surfactants determination at submicrogram to microgram per liter levels in wastewaters. Inter-laboratory precision values were calculated as the reproducibility relative standard deviation (RSD(R)) which was determined from the reproducibility standard deviation (sR) and the average concentration at a particular concentration level. When data from all laboratories were pooled, the RSD(R) values ranged from 5.1 to 28.3% for the determination of target analytes. The most accurate result corresponded to that given for linear alkylbenzene sulfonates. Taking into account that different methodologies were used (including non-chromatographic techniques) and the complexity of the samples analyzed, it can be considered that acceptable reproducibility values were obtained in this inter-laboratory study.


Assuntos
Cromatografia Líquida/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Tensoativos/análise , Poluentes Químicos da Água/análise , Espectrometria de Massas/métodos , Esgotos/análise , Água/análise
20.
Anal Biochem ; 279(1): 46-54, 2000 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-10683229

RESUMO

A noncompetitive flow immunoassay system (FIA) for the analysis of interleukin-8 (IL-8) in cell samples was developed. Affinity interaction assays based on offline incubation of excess labeled antibodies and antigen (IL-8) were carried out. The residual unbound labeled antibody was trapped in an immunoaffinity column with immobilized IL-8 while the immunocomplex, labeled antibody/IL-8, was detected by a fluorescence detector. Two fluorophores, FLUOS and Cy5.5, were conjugated with IL-8 antibody. Optimization and comparison between the two fluorescent labeled antibodies were performed with regard to pH, antibody concentration, flow rate, injection volume, and association time. Additionally, a horseradish peroxidase enzyme label was used for the conjugation to the anti-IL-8. The enzyme substrate reaction was optimized with respect to temperature and length of the substrate reaction coil. The detection limits were found to be 200 amol using the FLUOS-labeled anti-IL-8 and 1 fmol using the Cy5.5 fluorescence label. The developed FIA technique was applied for the analysis of IL-8 in cell samples. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was used to identify IL-8 in the cell samples.


Assuntos
Fluorimunoensaio/métodos , Interleucina-8/análise , Anticorpos , Carbocianinas , Células Epiteliais/imunologia , Estudos de Avaliação como Assunto , Fluoresceínas , Corantes Fluorescentes , Fluorimunoensaio/instrumentação , Fluorimunoensaio/estatística & dados numéricos , Peroxidase do Rábano Silvestre , Humanos , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...